5Plate fixation to proximal fragment

Insertion of second screw into proximal fragment

Confirm the mid-lateral plate position using two Hohmann retractors introduced through a second incision over the proximal plate portion, or by palpation.

Once the most proximal screw is fully inserted, the more distal screw in the proximal fragment is finally tightened.