previous section: 6/7 page: 5/6 next

6Lag screw insertion

Inserting and fully tightening bone screw

Screw insertion

Insert the 6.5 mm partially threaded cancellous bone screw and fully tighten. In the case illustrated, the partially threaded screw will have 32 mm of thread, as opposed to 16 mm of thread.

Note: a washer may be used, particularly in osteoporotic patients.