previous section: 4/4 page: 5/11 next

4Fixation

Tighten the wire

Once the fragment is reduced, the wire loop is tightened, cut short, and bent along the phalanx, in order to avoid soft-tissue irritation.
When tightening the wire, ensure that both ends are twisted around each other rather than twisting one end around the other straight end.