previous section: 6/8 page: 5/7 next

6Screw and cerclage wire

The wire ends are cut 1 cm away from the proximal screw head and the remaining end pressed down onto the bone. The two screws are subsequently fully tightened. This provides additional compression across the growth plate by the wire loops moving along the screw heads proximally and distally, respectively.

Each stab incision is closed with one or two interrupted sutures.