previous section: 4/11 page: 7/7 next

4Anterior column: reduction

Usually the reduction plate is assisted with lateral femoral traction and the use of a Farabeuf clamp in the ASIS to obtain correct reduction.

Final fixation with a long reconstruction plate along the pelvic brim may require removal of the reduction plate.