previous section: 4/6 page: 2/2 next

4Open Reduction

A smooth K-wire is placed through the radial styloid across the fracture site into the opposite radial cortex to secure the reduction.

Further K-wires may be inserted to reduce and hold the remaining articular fragments.

Accurate anatomic reduction of the articular surface must be confirmed, before the plate is applied.