previous section: 7/8 page: 1/5 next

7Plate fixation

Insert first screw

Insert a conventional screw through the oblong plate hole. The screw should engage the far cortex.

Confirm plate position using image intensification. Fine tuning of the plate position is still possible before the conventional screw is tightened.