6Plate fixation

Insert a screw through the oblong plate hole, using a screw long enough to engage the opposite cortex. Do not fully tighten the screw yet.

Confirm the reduction and plate position using image intensification. If necessary, adjust the plate position until it is as distal and as ulnar as possible. Now tighten the screw.