3Pedicle screw insertion (MIS)

Pedicle screw insertion

Pedicle screws are inserted one or two levels above and below the tumor on both sides. Mono- or polyaxial top or side loading screws can be used in any combination.

In tumor patients achieving optimal screw purchase is even more important than in trauma patients to minimize risk of pullouts and reduce the number of levels involved.

Optimal pedicle screw purchase will, in order of importance, be achieved by:

  1. Selecting the largest possible screw diameter
  2. Selecting the longest possible screw
  3. Positioning of the screw under the cranial endplate
  4. Cement augmentation of the screw.