previous section: 3/10 page: 8/8 next

3Creation of the nail entry site

Curved solid awl

Alternative: curved solid awl

In addition to cannulated cutting tools, or drills, the cortex can be opened with a solid awl.
The important principle is that the entry site must be placed so that the nail enters the tibia freely, and does not disturb the anatomical fracture alignment. This is very important for proximal tibial fractures.