Executive Editor: James Hunter

General Editor: Fergal Monsell

Authors: Andrew Howard, Peter Schmittenbecher, Theddy Slongo

Pediatric forearm shaft 22-D

ESIN

1. Introduction

General considerations

The ESIN method involves closed reduction and internal fixation with an elastic nail.

This method is a commonly used treatment option for displaced and/or unstable fractures of the forearm.

It can be used in any age group and any combination of fracture types.

ESIN without image intensifier

The ESIN method is possible without an image intensifier or peroperative x-ray examination.

The procedure is modified to include direct visualization of the fracture with an open approach. Stripping of the periosteum and disruption of the fracture hematoma are disadvantages.

2. Order of fixation

Placing the nail in the radius first is often advantageous.

If the radius reduces easily then the ulnar entry point can be selected to be furthest from the ulnar fracture.

If the radius is difficult to reduce a distal ulnar entry point should be used to place both nails in the same direction to the level of the fracture site. This allows simultaneous closed manipulation of both fractures and easy imaging.

3. Patient preparation

This procedure is normally performed with the patient in a supine position .

4. Reduction and fixation of the radius

The steps required for radial fracture fixation are described in the ESIN procedures for each fracture type:

5. Reduction and fixation of the ulna

The steps required for ulnar fracture fixation are described in the ESIN procedures for each fracture type:

6. Simultaneous reduction and fixation of both fractures

The radius is always nailed in a retrograde direction.

The ulna can be nailed in an antegrade or retrograde direction.

In the following description of an unstable oblique both bone midshaft fracture, the setup is illustrated with the distal lateral (radial) and medial (ulnar) entry points .

The technique is the same for greenstick, transverse, or multifragmentary fracture types in combination.

7. Instruments and implants

Instrument set for ESIN
  • 1.5-2.5 and occasionally 3.0 mm elastic nails
  • Alternatively: 30 cm long, 1.6-2.5 mm K-wires with the tip bent
  • Awl or drill
  • Inserter
  • Nail cutter
  • Small hammer
  • Optional: end caps

The end cutter is useful to avoid sharp ends and soft-tissue irritation.

Use of K-wires

Ring fixator wires may be used.

Bend the tip by approximately 30° to provide a gliding aid.

Nail diameter

For optimal reduction and intramedullary three-point fixation, the nail diameter should be between 60% and 70% of the medullary canal.

8. Technique

Preliminary reduction

Preliminary reduction is not useful as deformity usually recurs following manipulation.

Opening the canals

Use small scissors or a surgical clip and small retractors to dissect to the bone under direct vision.

Note: Avoid injury to the superficial radial nerve and the cephalic vein.

Place the awl or drill directly onto the bone and perforate the near cortex, under direct vision, perpendicular to the bone.

Do not hammer the awl to avoid perforation of the far cortex.

When the medullary canal is reached, lower the awl or drill 45° to the shaft axis and advance it with oscillating movements to produce an oblique canal.

Nail insertion

Precontouring the nail for forearm shaft fractures may be required.

The medullary canal is small, and the nail may deform during insertion.

Fix the nail into the inserter and pass it into the canal.

Pearl: It is helpful to use two inserters to avoid repetitively changing from one nail to the other. A universal chuck may be used as the second inserter.

Pearl: insertion of nail tip perpendicular to shaft

Insert the nail with the tip perpendicular to the shaft axis until the far cortex is felt. Rotate the nail 180° and advance it using the curved side of the tip as a gliding aid.

If the tip is stuck in the far cortex and cannot be advanced, remove the nail and bend the tip to give a slightly more pronounced curvature.

Advancing the nails

Advance the nail to the fracture site with an oscillating maneuver.

Pearl: A short working length (3-5 cm) between the entry point and the inserter improves control of the nail during insertion.

Pitfall: iatrogenic fracture

In young children, the nail tip may become stuck because of the narrow medullary canal.

Do not use a hammer if the nail is stuck as this risks iatrogenic fracture.

Withdraw by 2 cm, rotate the nail to free the tip and continue advancing.

Reduction with nail

Point one nail tip toward the opposite fracture plane using the other nail to achieve reduction by a combination of traction, angulation and translation. At this point gentle hammer blows may assist insertion and prevent the nail from advancing into the soft tissues. Advance the nail 2 cm into the proximal fragment.

Closed reduction

If the nails cannot be advanced into the proximal segment, manipulate the distal fragments under image intensification.

Approximate reduction of one fracture is achieved with distraction, rotation and joystick maneuvers of the nails.

The radius is usually stabilized first (as illustrated).

Passing the second nail may require rotating the first nail back to the initial position.

Use an image intensifier to check correct nail position in both bones.

In the case of a multifragmentary transverse fracture (22-D/4.2), thread the nail through the floating segment.

In case of a wedge fracture (22-D/5.2), sufficient bone contact is necessary for axial stability avoiding redisplacement and telescoping. If there is length instability the use of end caps is recommended.

The major fragments are reduced and the wedge fragment is not disturbed.

Open reduction

If neither of the fractures can be reduced after three attempts, open the radial fracture zone for reduction and advance the nail into the proximal fragment under direct vision.

If an image intensifier is not available, then an open procedure is necessary.

Make a small skin incision over the radial fracture zone followed by a small incision in the deep fascia.

The fracture often causes soft-tissue stripping and the fragments are located with blunt finger dissection.

Insert two small retractors so that both fracture ends are visible.

Pearl: Before opening the fracture, a threaded K-wire may be used to manipulate the proximal fragment.

After reduction of the radial fracture, the ulnar fracture may reduce closed allowing the nail to pass.

If this is not possible make a separate incision for open ulnar reduction.

Pitfall: risk of compartment syndrome

Repeated attempts to achieve closed reduction and fixation may increase the risk of compartment syndrome.

The compartment status should be checked within 6 hours.

Finalizing nail position

Advance the nails up to the strong metaphyseal bone.

Place the forearm in supination with the nail tips facing each other to tension the interosseous membrane.

Pearl: estimation of nail length

If an image intensifier is not available, estimate the optimum nail length with a second identical nail placed parallel to the initial nail.

Cutting the nails and wound closure

Cut the nail near the bone.

If a dedicated nail cutter is not available, cut the nail slightly shorter as the end will be sharper and this prevents skin perforation.

Gently withdraw the nail by 1 cm, cut the nail outside the skin and reinsert to the original position with an impactor.

When using the lateral entry point, ensure that the nail tip does not irritate the superficial radial nerve.

When using the dorsal entry point, the nail should be left long or protected with small end cap to prevent rupture of the extensor pollicis longus.

Close the subcutaneous tissue and skin in a standard manner.

9. Option: end caps

End caps may be useful for:

  • Stabilization of length unstable fractures
  • Protection of soft tissues (eg EPL)

The nails should finally be advanced using the beveled impactor.

A small end cap can be inserted over the nails using the inserter.

10. Final assessment

Check the completed osteosynthesis with image intensification. These images should be retained for documentation or alternatively an x-ray should be obtained before discharge.

Make sure that the desired reduction has been achieved and the nails are of appropriate length.

Appendix

Shortcuts

Decision support

Contact | Disclaimer | AO Foundation

v1.0 2018-11-28