Executive Editor: Jörg Auer

Authors: Lawrence Bramlage

Phalanges Fetlock joint, Disruption

back to skeleton

Glossary

1 Principles top

enlarge

Tension band

Because the plate is placed on the dorsal aspect of the fetlock joint and would be subjected to severe bending if not protected, a tension band must be placed on the palmar/plantar aspect of the fetlock joint. The tension band can be created by two means:

  1. Inserting cortex screws in lag fashion from the dorsal and distal aspect of McIII/MtIII into the proximal sesamoid bones uses the inelastic distal sesamoidean ligaments to create the tension band (left).
  2. If the proximal sesamoid bones or distal sesamoidean ligaments have been disrupted by the injury, the tension band is created using a double strand of 1.5 mm wire (right).

enlarge

The principles of fixation are the same. The technique varies slightly depending on the injury.
A biaxial proximal sesamoid bone fracture will be used as the injury in the following illustrations.

2 Plate selection and preparation top

enlarge

Plate selection

A broad plate of 14-16 holes is normally selected based upon the size of the horse. A dynamic compression plate (DCP or LC-DCP) or a locking plate (LCP) can be used for stabilization.
Some surgeons prefer a 10-hole LCP. In the following, the technique will be shown with an 14-hole DCP.


enlarge

Plate position

Maximum purchase needs to be obtained in the proximal phalanx, so as many screws as available should be inserted into the proximal phalanx.
The proximal end of the plate is placed at the proximal diaphyseal-metaphyseal junction of McIII/MtIII.

Care should be taken to place the plate on the long axis of both bones, the proximal phalanx and McIII/MtIII.


enlarge

Plate preparation

The plate is contoured to place the fetlock in 15-20 degrees of dorsal extension.


enlarge

3 Option A: Creating a tension band with wire top

enlarge

Drilling the holes for the wire

If the wire is needed to create the palmar/plantar tension band, it is inserted with the joint luxated. A 3.2 mm hole is pre-drilled, with the joint reduced, in the dorsal plane in the mid-portion of the proximal phalanx prior to luxation of the joint. A second 3.2 mm hole is also created in the dorsal plane through the distal McIII/MtIII in similar distance proximal through the joint.

Note: care must be taken to place this hole in an area distant from the plate holes in the proximal phalanx. Therefore it may be advantageous to drill all four plates holes in the proximal phalanx prior to preparing the hole along the frontal plane.


enlarge

Application of the wire

A 1.25 mm cerclage wire is threaded through the proximal phalanx with the joint luxated and then passed behind the proximal phalanx into the fetlock joint on its palmar/plantar surface.
The other end of the wire is then crossed on the palmar/plantar aspect of the proximal phalanx, passed up the medial aspect of the distal McIII/MtIII, and threaded through the hole in the parent bone and the condylar fracture.
A second 1.25 mm cerclage wire is threaded in reverse fashion through the two holes such that the wire ends come to rest at the medial aspect of the distal McIII/MtIII.


enlarge

The iatrogenic condylar fracture is subsequently reduced and reattached to the parent bone with a cortex screw in lag fashion.
The two figure-8 wire loops are twisted on the lateral an medial aspect of the bone with the fetlock joint in 10 degrees of flexion. (It is important to tighten the wire in slight flexion so that when the limb is again placed in extension, the wire comes under tension.)


enlarge

Plate application

The plate is reattached to the proximal phalanx.

4 Option B: Creating a tension band using the sesamoid bones top

enlarge

Plate application

The iatrogenic condylar fracture is reduced and reattached to the parent bone with a cortex screw in lag fashion.
The plate is then reattached to the proximal phalanx.


enlarge

Placing the screws for the tension band

If the distal sesamoidean ligaments are being used to create the tension band, the screws are placed at this time.
One cortex screw is inserted using lag technique through the distal aspect of McIII/MtIII into each of the proximal sesamoid bones to stabilize the sesamoid bones and the distal seamoidean ligaments to the back of McIII/MtIII creating the tension band.
(It is important to place the screws in slight flexion so that when the limb is again placed in extension, the distal sesamoidean ligaments come under tension.)


enlarge

Intraoperative example.

5 Finalize plate fixation top

enlarge

The plate is then depressed to the surface of McIII/MtIII to create tension in the distal sesamoidean ligaments or the wire.


enlarge

The tension device is attached to McIII/MtIII at the proximal end of the plate.

The tension device is tightened into maximum tension using the appropriate wrench.


enlarge

The remaining screws are inserted in the plate.


enlarge

Transarticular screws

Once all screws are in the plate one 5.5 mm cortex screw is placed in lag fashion medially and laterally through the proximal phalanx into the distal McIII/MtIII taking care not to interfere with the implants already in place in the limb.
These two lag screws increase the stability and resistance to rotation at the fetlock joint.


enlarge

Completed fixation with cerclage wires.

6 Closure top

enlarge

At this point, prior to closure, the surgeon may decide to use a bone graft, antibiotic containing implants and/or suction drainage depending on the injury.


enlarge

enlarge

Closure of the incision requires coaptation of the previously split extensor tendon, joint capsule and extensor branch of the suspensory ligament over the implants. The subcutaneous tissue and skin are then closed sequentially.

v1.3 2013-11-20