Executive Editor: Jörg Auer

Authors: Patricia Hogan

Phalanges - Proximal sesamoid bones, Base

back to skeleton

Glossary

Base fracture of the proximal sesamoid bone - removal enlarge

Arthroscopic examination

In lateral recumbency the arthroscope is inserted through the palmar pouch, whereas the instruments are inserted through a separate incision at the level of the fracture plane.


Base fracture of the proximal sesamoid bone - removal enlarge

The arthroscope is inserted and the fracture configuration inspected...


Base fracture of the proximal sesamoid bone - removal enlarge

... and identified.


Base fracture of the proximal sesamoid bone - removal enlarge

Fragment removal

The fragment or occasionally fragments are freed from their attachments of the distal sesamoidean ligaments with the help of sharp instruments such a scalpels, special curved small osteotomes or sharp periosteal elevators. Loosening occurs proximally, axially, and abaxially. Once freed up the fragment is grabbed with Ferris-Smith rongeurs and rotated to free up the last attachments and finally removed as a whole. Occasionally the fragment has to be split in half to remove it.

Dependent upon the size of the fragment the instrument incision may have to be enlarged for fragment removal.

The use of an arthrobur to grind down the fragment and remove the debris via suction is not encouraged because only the articular component of the fragment can be visualized.


Base fracture of the proximal sesamoid bone - removal enlarge

Debridement and inspection of the fracture bed

Once the fragment is removed, the joint is thoroughly inspected and any remaining debris or any small fragments are emoved. Special attention is given to the ligamentous attachment remains, which are checked for osseous remains attached to them.


Base fracture of the proximal sesamoid bone - removal enlarge

It is advisable to take intratroperative radiographs to assure that the entire fragment is removed. Intraoperative fluoroscopy represent another option.


Base fracture of the proximal sesamoid bone - removal enlarge

Closure and radiographic control

The joint is thoroughly lavaged, the excess fluid removed from the joint, the arthroscope removed and the incisions closed using routine technique. A sterile pressure bandage is applied to the limb with the horse still on the table.

At the end of the procedure it is advisable to take radiographs while the horse is still on the table to assure that all fragments are removed.

v1.3 2013-11-20