Executive Editor: Jörg Auer

Authors: Patricia Hogan

Phalanges Proximal sesamoid bones, Midbody

back to skeleton

Glossary

1 Principles top

Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

Anatomic reduction

Precise anatomic reduction of the articular surface of the proximal sesamoid bone is the most critical and yet most difficult part of the surgical procedure.
The proximal fragment is subject to multiple twisting and sliding forces and can be very difficult to be maintained in alignment during the surgery. Frequent arthroscopic evaluation is required to ensure perfect reduction prior to screw placement.
Less than perfect reduction results, aside from the development of degenerative joint disease, in cyclic fatigue of the implant(s) and may lead to premature screw breakage.


Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

Number of screws

The proximal sesamoid bone has a relatively small pyramidal shape that leaves little room for error with screw placement. Insertion of two screws would be ideal to increase the stability of the fixation and counteract torsional forces upon the fixation, but accurate placement requires significant skill and planning.
The author’s preference is a combination of a 4.5 mm and a 3.5 mm screw to optimize compression and counteract rotational forces within the space limitations of the bone.


Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

Intraoperative imaging

Advanced imaging such as fluoroscopy is an advantage. If not available, frequent intraoperative radiographic monitoring and insertion of anatomical markers are used to help the surgeon to implant the screws accurately.
The following description of the procedure uses standard radiography as imaging modality.


Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

2 Insertion of the arthroscope top

Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

A standard arthroscopic approach is made to the palmar/plantar pouch, taking care to place the arthroscope in the most proximal aspect of the pouch.
The fracture is visualized and any relevant comminution along the fracture line is debrided.

3 Fixation top

Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

Placement of radiographic markers

If advanced imaging technologies are not available, 19 gauge 1.5 inch (3.8 cm) needles are used as radiographic markers to assist the surgeon with screw placement.
The needles are placed under arthroscopic supervision at the apex, base, and fracture line of the proximal sesamoid bone in both the frontal and sagittal planes.


Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

Stab incisions

Screw placement is performed either in proximal to distal or distal to proximal direction depending on the fracture configuration and the surgeon’s preference. Most commonly, the screws are inserted from distal to proximal, as described in the following steps.
A stab incision is placed palmar/plantar and median to the vascular bundle at the base of the proximal sesamoid bone. If two screws are inserted, two parallel stab incisions are placed.


Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

Screw insertion

Standard lag technique is applied. Intraoperative diagnostic imaging is strongly encouraged to determine when the glide hole reaches the fracture plane and to prevent inadvertent overdrilling of part of the proximal fragment, which would result in a weakened fixation. It is critical not to lose contact with the drill hole when the drill guides are changed. Therefore a K-wire is used to fill the hole once the large drill is removed and to facilitate placement of the small drill guide in the glide hole.

Countersinking is not recommended because the screw head comes to lie in the natural concavity located at the base of the proximal sesamoid bone and origin of the different distal sesamoidean ligaments in the area.


Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

A longer drill bit (180 mm) is recommended to avoid interference of the drill with the bulbs of the heel and in doing so impede the ability to maintain the correct drilling angle.

It is helpful to have an assistant dorsiflex the foot to allow more room for the drill.


Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

When two screws of different sizes are placed, the 4.5 mm screw is preferably inserted more axially.

Final tightening of the two screws is performed in an alternating pattern.


Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

Proper placement of the screw(s) is confirmed both radiographically ...


Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

... and arthroscopically.

4 Alternative: screws from proximal to distal top

Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

Occasionally, the orientation of the fracture line does not allow routine screw insertion from the base of the bone. In these cases the screws are implanted in  proximolateral to distomedial direction.


Midbody fracture of the proximal sesamoid bone - screw fixation enlarge

The same principles apply for surgical repair, but some difficulty with screw placement may be encountered at the abaxial margins of the proximal fragment, because of the uneven, slanted bone surface in this location.

v1.3 2013-11-20