Executive Editor: Chris Colton

Authors: Mariusz Bonczar, Daniel Rikli, David Ring

Distal humerus 13-A2.3 Sling with or without splinting

back to skeleton

Glossary

1 Principles top

enlarge

Anatomical consideration

The distal third of the humerus is flattened in the coronal plane and curves anteriorly.


enlarge

Sometimes, the olecranon fossa and the opposing coronoid fossa communicate through an opening, the supratrochlear foramen.

Stability of the distal third of the humerus depends on the lateral and medial supracondylar columns linked distally, as a trianlge. by the condylar mass. Any rotation causing loss of bony contact decreases fracture stability.


enlarge

Distal articular surface

The medial part of the trochlea extends more distally than the lateral part and the capitellum, resulting in a valgus humero-antebrachial geometry ("carrying angle"). With the elbow extended, the long axis of the forearm makes an angle of approximately 6° to the long axis of the humerus in the coronal plane.


enlarge

During elbow flexion the forearm moves on a plane such that the hand goes directly towards the mouth. Any changes in the valgus position after the reduction will strongly distort the original plane of movement. 


Requirement for splinting

In compliant patients with minimally displaced fractures it may be reasonable to support the limb in a sling without appying a splint. If it is felt that the patient or the fracture need s any protection, it is sensible to apply a splint.


enlarge

Tendency to malalignment

There is a tendency to malalignment and to secondary anterior displacement after reduction.


enlarge

Similarly, there is the risk of rotation and rotational malposition of the fragments. Reduction is made more difficult by the weight of the forearm acting on the fracture site.


Deformity

Healing with any deformity (angulation, malrotation, and / or shortening) will usually cause significant elbow dysfunction. The restoration of normal elbow anatomy (anatomical reduction) is of high importance.


enlarge

Nerves around the distal third of the humerus

Nerves on both sides of the distal humerus run very closely to the bone, especially the ulnar nerve, which perforates the medial intermuscular septum runs and then in its sulcus behind the medial epicondyle. It can be directly compressed in distal humeral fractures. The radial nerve perforates the lateral intermuscular septum as it loares the spiral groove on the humerus, torun anteriorly and distally. At the level of the radial head it divides into its deep and superficial branches.

Note
The median nerve crosses the anterior capsule of the elbow joint, running into the forearm between the two heads of the pronator teres muscle.

2 Reduction top

The majority of displaced fractures would be treated operatively. If a displaced fracture is to be treated nonoperatively, attempts should be made to reduce the fracture.


enlarge

Distract the fracture

The reduction is performed under general anesthesia, or using an axillary block.

The arm is pulled with one hand while the other hand palpates the bony eminences of the distal humerus, ie, medial and lateral epicondyles. Distraction of the fracture is obtained by pulling the forearm.


enlarge

Flex elbow

Flex the elbow up to 90°, whilst maintaining the distraction the whole time - as the elbow flexes the reducing hand also applies distraction.


enlarge

Correct rotation

Correct any rotational displacement by applying force to the forearm, whilst still distracting. Once reduction is complete, the distraction is gently discontinued.

3 Fracture splint management top

enlarge

Apply cast padding

With the patient sitting, if possible, cast padding should be wrapped around the upper arm, elbow, forearm and hand, down as far as the transverse crease of the hand (leave the MP joints free). Keeps the elbow in 90° flexion and the forearm in neutral rotation. Make sure that the epicondyles of the humerus and the antecubital area are well padded.


enlarge

Apply splint

A splint of fiberglass, or plaster, is applied on the posterior aspect of the arm and forearm. It should be wide enough to cover more than half of the circumference of the arm and forearm. It is secured with an elastic bandage that should not be too tight.


enlarge

Sling

The injured arm is supported in a sling.


enlarge

Analgesia

Analgesia will be required. The patient is usually more comfortable in a sitting or semireclining position, with the elbow elerated on pillows at least for the first few weeks. Fragment motion and crepitus may well be perceived, and the patient should be reassured that this is normal, stimulates healing, and will gradually settle.

v1.0 2007-06-21