Executive Editor: Chris Colton, Steve Krikler

Authors: Pol Rommens, Peter Trafton, Martin Jaeger

Humeral shaft - Wedge fracture, intact wedge

back to skeleton

Glossary

1 Principles top

Generic fracture patterns enlarge

Note on illustrations

Throughout this treatment option illustrations of generic fracture patterns are shown, as four different types:

A) Unreduced fracture
B) Reduced fracture
C) Fracture reduced and fixed provisionally
D) Fracture fixed definitively


Bridge plating enlarge

Bridge plating

Bridge plating uses the plate as an extramedullary splint, fixed to the two main fragments, while the intermediate fracture zone is left untouched. Anatomic reduction of the shaft fragments is not necessary. Furthermore, direct manipulation risks disturbing their blood supply. If the soft-tissue attachments are preserved, and the fragments are relatively well aligned, healing is predictable.

Alignment of the main shaft fragments can usually be achieved indirectly using traction and soft-tissue tension.

Mechanical stability, provided by the bridging plate, is adequate for indirect healing (callus formation). Occasionally, a larger wedge fragment might be approximated to the main fragments with a lag screw. Lag screws should be avoided when there is significant comminution.

To illustrate the principles of bridge plating in humeral shaft fractures, the anterolateral plate application through an anterolateral approach is described. The application of a posterior plate follows the same principles.


Bridge plate insertion

With open bridge plating, it is important to preserve soft-tissue attachments to the fracture fragments. To do this, stable provisional reduction (with external fixation, large distractor, or maintained manual traction), and minimal exposure and manipulation of the fracture zone are important. The bridge plate is applied through an incision just long enough for the plate.

2 Choice of implant top

Choice of implant enlarge

Either a standard plate or a plate with locking head screws (LCP) can be used as a neutralization device. In poor quality bone the use of an LCP is recommended.

As bridge plating should span a long section of the bone, the length of the implant has to be chosen accordingly. It should be long enough to allow sufficient hold in the proximal and distal segments, generally a minimum of three bicortical screws in each. Typically, a ten or twelve-hole 3.5 mm LCP is sufficient. It is also possible to use a long PHILOS plate.

Longer plates are normally twisted to form a helix, so that the proximal end is applied to the lateral humerus while the distal end lies on the anterior surface.

3 Plate position top

Plate position enlarge

Introduction

The choice of plate position depends on the fracture morphology and location, the radial nerve pathology and the surgeon’s preference. The anterolateral, anterior, and posterior surfaces of the humeral shaft are all possible choices.

The medial surface is generally reserved for complex reconstructive procedures ie vascular repair in complex fractures. Since the use of this plate position is rare it is not further shown.

The location should allow sufficient plate length on both proximal and distal segments, with a minimum of three holes for each.


Anterolateral plate enlarge

Anterolateral or anterior plate

An anterolateral plate fits well from very proximally to the distal fifth of the humerus and is selected if proximal and middle third fractures are present. The anterolateral or extended deltopectoral approach may be used in a supine position or, alternatively, a beach chair position.

A plate in this position should provide stable fixation of the fracture and minimal soft-tissue damage.

Proximally, the plate may interfere with the deltoid insertion if it is placed laterally, or with the long head of the biceps tendon if the plate is positioned anteriorly. To overcome these problems the proximal end of the plate can be tunneled through the deltoid insertion.


The plate may need to be contoured and/or twisted to form a helix. enlarge

Distally the plate may be applied to the anterior or lateral surfaces.

Depending on the chosen positions for the proximal and distal plate ends, the plate may need to be contoured and/or twisted to form a helix.


The radial nerve is at risk if the plate is applied to the lateral surface in the distal third. enlarge

Neurological considerations should be taken into account. The radial nerve is at risk if the plate is applied to the lateral surface in the distal third. The plate should be twisted to ensure that the distal end avoids damaging the radial nerve.


Brachialis split enlarge

The innervation of the brachialis muscle is derived from both the radial and musculocutaneus nerves. The radial branch is at risk if the plate is applied to the anterior and anterolateral surfaces in the distal third while retracting the entire brachialis muscle medially. To avoid this it is safer to split the brachialis muscle.


If a small open fracture wound is present, the approach is made separately. Only if there is a large wound, after debridement, consider using the wound itself, with its necessary extensions, for plate insertion.


Posterior plate enlarge

Posterior plate

The posterior surface is difficult to access proximally and limited by the axillary nerve. Therefore, posterior plating is best suited for middle and distal third fractures.

The posterior surface can be accessed with a posterior approach in a prone or lateral decubitus position.

It is important to protect the radial nerve and its accompanying vessels in the spiral groove. If the plate interferes with the radial nerve, the plate must be placed underneath it. The course of the radial nerve in relation to the plate holes should be mentioned in the operation note. This will reduce the risk of accidental nerve damage if the plate should ever need to be removed.

4 Reduction top

It is important to restore axial alignment and rotation. A little shortening of 1 or 2 cm can be accepted in the humerus, and in complex multifragmentary fractures may improve bone contact.


Manual reduction - limb realignment enlarge

Manual reduction - limb realignment

Begin the reduction with traction on the distal humerus restoring bone length, tension in the soft tissues, realignment of the axis, and rotation.

Clear any interposed soft tissue by direct exposure. Preserve as much soft-tissue attachment as possible.


Pointed reduction forceps enlarge

Pointed reduction forceps

When large fragments have significant muscle attachments, such as deltoid or pectoralis major insertion, they are often pulled away from the fracture zone. They should be reduced and held with reduction forceps while the plate is applied.

If there is concern that the fragment(s) will redisplace it may be secured with a screw or cerclage wire.


Reduction by external fixator or distractor enlarge

Reduction by external fixator or distractor

Use of an external fixator or distractor can provide alignment and stability for bridge plating without disturbing the soft tissues at the fracture site.

Insert proximal and distal pins outside the planned plate location. Take care not to injure the radial nerve. If in any doubt use incisions wide enough to allow palpation or direct visualization of the radial nerve.

Complete reduction may require additional correction of angulation or rotation. Folded linen bolsters under the fracture often help.

5 Plate fixation top

Contouring the plate enlarge

Contouring the plate

Depending on the planned plate location, some contouring of the plate is likely to be necessary to fit the plate to the bone perfectly so that tightening its screws does not displace the fracture. This is true distally, posteriorly, and also on the anterolateral surface centrally. Sometimes twisting the plate around the shaft of the humerus provides a better fit and allows a longer plate.

Shape a malleable template to the bone surface. Use this template as a guide to shape the plate to fit the bone.

Use care to avoid fracture displacement while contouring the plate.


Pitfall: avoid soft-tissue damage

During contouring and application of the bridge plate, the soft tissues attached to the fracture fragments must be preserved. Provisional fracture stabilization and minimal handling of the fracture site are the keys to this.


Plate application enlarge

Plate application

Apply the properly contoured plate to the proximal fragment, so that it is correctly aligned with the humeral axis.

When the plate fits satisfactorily against the proximal fragment, attach it provisionally with a single bicortical nonlocking screw while holding it manually against the bone. Alternatively, a locking screw can be used at this moment if the reduction and plate position does not need further adjustment. Sometimes it is helpful to clamp the plate to the proximal fragment of the humerus with bone forceps.

Apply the plate to the distal fragment to correct rotation and axial alignment.

Check in the lateral view that the plate is parallel to the longitudinal axis of the humerus.


Alignment and fixation of the distal fragment enlarge

Alignment and fixation of the distal fragment

Once the plate is fixed proximally, bring the distal fragment into alignment against the plate.

Hold the plate manually against the bone and check reduction and plate position. If necessary, loosen the screw in the proximal fragment and adjust the plate position. Occasionally it is necessary to remove the plate and perform further contouring.

Once reduction and plate position are satisfactory insert a first distal screw.

Sometimes it is helpful to clamp the plate to the humerus with bone forceps as shown. Carefully pass the forceps close against the bone during application to avoid injury to adjacent nerves.


Push-pull reduction device enlarge

Another option is the use of the push-pull reduction device, from the LCP set, as shown here. Choose a hole which will not be used for final screw fixation.


Insert the first distal screw. enlarge

Insert the first distal screw. Depending on the fixation technique either a nonlocking or a locking screw can be used near by the fracture site.


Finalizing the fixation enlarge

Finalizing the fixation

If the alignment is satisfactory, add the remaining screws to both main fragments and reconfirm alignment.

The number of screws depends on the type of screws, the fracture morphology and the bone quality.

Using locking screws, two bicortical screws on each side may be sufficient, otherwise, it is recommended to use 6 fixation points on each side. For both major fragments, place one locking screw close to the fracture, and the second at the end of the plate.

Confirm the reduction, plate position, and screw length under image intensification.

Confirm rotational alignment by physical examination.

6 Option: fixation of large wedge fragment top

Option: Fixation of large wedge fragment enlarge

Bridge plating does not involve fixation of comminuted fragments.

However, when a large wedge fragment remains significantly displaced from the rest of the humerus, its position and stability may be improved with a reduction of this fragment.

Approximation, rather than anatomical reduction, is used to avoid soft-tissue disruption. Free the wedge fragment carefully from interposed muscle and hold it with a sharp hook or periosteal elevator. For fixation use either a lag screw (through or outside the plate) or cerclage.

If cerclage is used, take care not to injure the radial nerve. Keep the cerclage passer close to the bone. In any doubt, pass it under direct vision.

Pitfall: Do not try to fix every comminuted fragment. This risks devascularization.

7 Final radiological assessment top

Check for proper reduction and implant position with image intensification in AP and lateral views.

Also confirm correct torsional alignment of the humerus.

v2.0 2018-12-28