Executive Editor: Fergal Monsell General Editor: Chris Colton

Authors: Andrew Howard, James Hunter, Theddy Slongo

Pediatric proximal femur 31-E/1.1

back to Pediatric overview

Glossary

1 Preliminary remarks top


enlarge

Avascular necrosis

Complete, unstable proximal femoral fractures carry a significant risk of avascular necrosis (AVN) of the femoral head. AVN can result from entrapping or rupturing the retinacular vessels during a closed reduction maneuver.

Decompression of hemarthrosis may reduce the risk of AVN. Detailed knowledge of the vascular supply of the femoral head is a prerequisite for safe treatment and the management of femoral neck fractures in children ideally requires experience in hip surgery.

If reduction is not required, in situ stable fixation may be applied.

Note: Care must be taken to rule out slipped capital femoral epiphysis (SCFE). Fractures can be distinguished from SCFE by a detailed history supplemented by appropriate x-ray examination and assessment; in unclear situations, an MRI is indicated.


enlarge

Approach and positioning

In situ fixation is performed either through stab incisions or a single short incision. The patient may be supine on a fracture table, or on a radiolucent table.


enlarge

Hardware selection

6.5, 7.0, or 7.3 mm cannulated screws are used for adolescents.

4.0, or 4.5 mm cannulated screws may be selected for younger children. Be aware that these screws are considerably weaker and prone to breakage if used in too heavy a child.

If cannulated screws are not available, modification of this technique allows standard screws to be inserted.


enlarge

If the child is too small for screw fixation, 2.0, 2.5, or 3.0 mm K-wires can be selected depending on the size of the child.

Larger K-wire diameters are preferred for stability. Threaded K-wires also increase stability.


enlarge

Implant insertion

Typically, two screws (or K-wires) separated vertically are inserted. This configuration may be more suitable in smaller bones.

An alternative is three screws (or K-wires) used in an apex-distal, triangular configuration, with the lower central screw (or K-wire) abutting the calcar.

Inserting a single central screw (or K-wire) does not provide rotational stability and is, therefore, less applicable for fractures, even though it is a common choice for SCFE.


enlarge

Pitfall: Secondary subtrochanteric fractures may occur if screws are inserted with an entry point distal to the level of the lesser trochanter.

2 Fixation top


enlarge

Guide wire insertion

Under image intensification, the first guide wire is inserted via the lateral cortex above the level of the lesser trochanter, to pass just above the calcar and into the center of the inferior half of the femoral head epiphysis.

A wire can be placed along the anterior surface of the femoral neck as an indication of the anteversion.


enlarge

Additional wires are inserted under image intensification according to the two- or three-screw configuration chosen.


enlarge

X-ray control

The wire positions are confirmed on AP and lateral x-ray images, using image intensification.


enlarge

If using a standard radiolucent table, the K-wire fixation is generally stable enough to allow positioning for a “frog” lateral view.

K-wires are repositioned as necessary.


enlarge

Images at multiple angles are used to confirm that the K-wires do not penetrate into the hip joint.

3 K-wire fixation alone top


enlarge

If K-wire fixation alone is used, the K-wires are cut and bent leaving them deep to the fascia lata.

Capsular decompression should be considered.

4 Screw fixation top


enlarge

Enlarging stab incisions

The stab incisions are enlarged to allow for screw insertion. The incision is deepened down to bone by spreading the tissues with an artery forceps or blunt scissors.


enlarge

Measuring screw length

A depth gauge is used to measure screw length.

If a dedicated cannula/depth gauge set is not available, then a K-wire, of the same length as that inserted, is placed onto the lateral cortex adjacent to the inserted wire, and the difference measured to determine the screw length.


enlarge

Drilling screw holes

The K-wires are overdrilled, through a soft tissue protector, with an appropriate sized cannulated drill bit.

Intermittent screening with an image intensifier is recommended to ensure that the guidewire does not penetrate into the hip joint as the drill advances.

Adolescents in particular have very dense, strong bone in the metaphysis near the growth plate and predrilling is recommended.

If cannulated screws are not available, then guide wires should be removed one at a time and an appropriate drill used.


enlarge

Screw insertion

Two, or three, cannulated screws are then inserted over the K-wires.

Note: Fully threaded cannulated screws are easier to remove later.


enlarge

X-ray control

Image intensification is used to confirm that the screw tip does not penetrate into the joint. Typically, 5 mm of epiphyseal bone/cartilage should remain between the screw tip and joint surface. Three, or four, threads lying within the epiphysis provides adequate fixation.

Pitfall: Screw penetration can occur, especially with eccentrically placed screws, even if not apparent on AP or lateral x-rays.

Dynamic, real-time image intensification, with a full range of internal and external rotation at different degrees of flexion, is useful to see how close the screw-tip is to the joint surface of the head.

Observing an approach/withdrawal of the screw tip helps in judging its position. Some surgeons supplement this examination with 3-D image intensification for confirmation.

Arthrography is useful to confirm correct wire and screw placement in the younger patient.


enlarge

Guide wire removal

The guide wires are removed, once the full complement of screws has been shown to be ideally positioned.

Capsular decompression should be considered.

5 Hip spica top


enlarge

If solid fixation has been obtained with screws, and the patient/family can reliably comply with toe-touch weight bearing, then a cast is not necessary.

For patients below 5 years of age, a hip spica cast can be used if desired.

Click here for details of hip spica application.

v1.0 2017-12-04