Executive Editor: Fergal Monsell General Editor: Chris Colton

Authors: Andrew Howard, James Hunter, Theddy Slongo

Pediatric proximal femur 31-E/2.1

back to Pediatric overview

Glossary

1 Preliminary remarks top

enlarge

Introduction

Children's hip fractures have historically had a bad prognosis. Accurate stable fixation has been one of the factors identified to improve the outcome.

The main problems have been avascular necrosis (AVN) due to disruption of the blood supply, nonunion and malunion due to unstable fixation.

The objective is timely fixation without disruption of the blood supply.

Angularly stable fixation using a pediatric hip locking plate is indicated for physeal injuries only if there is a large metaphyseal fragment (Salter-Harris II fractures).


enlarge

Implant selection

The choice of implant size depends on the age and weight of the child.

Generally, a 130˚ angled plate is appropriate for fracture fixation, as it corresponds most closely to the child's femoral neck-shaft angle. It offers the possibility of three parallel screws into the neck.

A plate with three shaft holes is sufficient for intracapsular fractures.

Longer locking screws, not included in the standard pediatric hip locking plate set, may be required.

2 Reduction top

enlarge

The first step, after capsulotomy, is to reduce the fracture.

Reduction is achieved by a combination of gentle traction, leg position, and direct reduction.

Reduction is facilitated by traction with a hook in line with the femoral neck.


enlarge

The use of one or two joysticks in the proximal fragment allows this to be aligned correctly.

Two joysticks at 90° to each other allows the proximal fragment to be moved in all planes.


enlarge

Temporary K-wire stabilization is useful at this stage. Care must be taken that the temporary K-wire does not prevent insertion of the definitive wires.

3 Fixation top

enlarge

Insertion of guide wires

After reduction, the guide wires for the pediatric hip locking plate are inserted.

This can be done using the dedicated angled guide, or by placing the wires through the plate with the screw-in guides attached to it.

An anteversion wire along the front of the femoral neck can be useful.


enlarge

A 2.0 mm guide wire should be inserted high in the neck, starting at least 5 mm below the trochanteric apophysis. This wire can be inserted using the angled guide, or freehand.

The position should be checked radiologically. On the lateral view, the wire should be in the middle of the femoral neck.


enlarge

After the initial 2.0 mm wire, two 2.8 mm wires will be inserted using the dedicated angled guide.

The 2.8 mm wires will sit just above the mid-point of the femoral neck on the AP view.

Once these two wires are inserted, the temporary fixation wire should be removed.


enlarge

Alternatively, these wires can be inserted through the plate with the locking guides attached.


enlarge

Plate application

With the three wires in place, the plate with locking guides can be slid over the wires onto the side of the femur.


enlarge

Screw insertion

The length of the screws is measured using a direct measuring device over the wire on the locking guide.


enlarge

At this stage, a decision should be made whether a compression screw is required. If it is, it should be inserted through the third hole in the proximal part of the plate before any other screws are inserted. The compression screw can be a cortical lag screw. The hole for this screw should be drilled parallel to the 2.8 mm K-wires.

Note: A compression screw, if used, must be inserted before any locking screws.


enlarge

After insertion of the compression screw, the locking screws should be inserted.

The guide wires are removed and replaced by locking screws, one at a time. This ensures that fracture reduction is maintained by at least two wires, or screws, at all times.


enlarge

If a compression screw has not been used, the third hole in the proximal part of the plate can be used to insert a further locking screw.


enlarge

The plate should be secured to the shaft using two, or three, locking screws. This prevents any disruption of the fracture fixation.

Definitive radiological images should be taken.


enlarge

Closure

The capsule should be closed loosely to prevent a hemarthrosis forming under pressure, which can compromise the blood supply.

Routine closure is performed for the remainder of the wound, according to the surgeon’s preference.

4 Aftercare top

enlarge

Immobilization and weight bearing

If the fixation is stable, no external immobilization is required.

After a day or two of bed rest, the patient can be mobilized toe-touch weight bearing, using crutches, or a frame.

Increased weight bearing can be introduced as the fracture is judged to be healing, depending on patient age. In an adolescent, partial weight bearing at 6 weeks and full weight bearing at 12 weeks would be typical.


Plate removal

If screws cross the physis, and a lot of growth potential remains, they should be removed when the fracture is healed and consolidated.

In small children, plate removal is advised to prevent bony overgrowth. Typically, this would be done at one year.

Plate removal is not compulsory in adolescents.

v1.0 2017-12-04