Executive Editor: Peter Trafton

Authors: Rahul Banerjee, Peter Brink, Matej Cimerman, Tim Pohlemann, Matevz Tomazevic

Pelvic ring - Primary survey, Airway

back to skeleton

Glossary

1 General considerations top

Prior to any evaluation, the cervical spine is immobilized to prevent possible injury to the spinal cord. The patient is positioned on a stiff trauma board.

2 Is the airway free? top

enlarge

The airway is patent if

  • Patient is conscious
  • Patient has a free speech

If airway is patent:

  • administer O2 (100 %, 12 L/min) using a bag-mask
  • The neck is immobilized using a cervical collar of the correct size.
  • Pulse oximetry monitoring is initiated
  • Patient is re-examined and if oxygen saturation < 95 %, evaluate whether this is caused by airway obstruction. Hypoxemia may also be caused by inadequate ventilation (Breathing), and/or Circulatory problems.
  • Proceed to evaluate breathing.

3 Further evaluation when the airway is not free top

enlarge

Clear the airway by suction

The airway is inspected and cleared manually or by suction.


enlarge

Unconscious patient – Insertion of oropharyngeal device

When the patient is unconscious the mandible is brought anteriorly to open the airway.

Perform a chin lift maneuver by lifting the mandible upward to bring the chin anteriorly.


enlarge

Alternatively a jaw-thrust maneuver can be performed by displacing the mandible forward. This maneuver can be performed in combination with the use of a bag mask device.


enlarge

To prevent airway obstruction by the tongue an oropharyngeal device is inserted with the concavity facing the palate and then rotated 180°.

This may need to be replaced by endotracheal intubation at a later stage.

If airway is patent:

  1. administer O2 (100 %, 12 L/min) using a bag-mask
  2. The neck is immobilized using a cervical collar of the correct size.
  3. Pulse oximetry monitoring is initiated
  4. Patient is re-examined and if oxygen saturation < 95 %, evaluate whether this is caused by airway obstruction. Hypoxemia may also be caused by inadequate ventilation (Breathing), and/or Circulatory problems.
  5. Proceed to evaluate breathing.

enlarge

Airway is still not patent or oropharyngeal device not accepted

When the airway is not patent or the patient does not accept an oropharyngeal device, one of the following techniques can be performed.

  • Laryngeal mask airway (LMA). This can be performed without anaesthesia, however cannot prevent aspiration completely.

enlarge
  • Endotracheal intubation is the safest way to establish a patent airway, but requires qualified personnel and the administration of anaesthesia drugs.

enlarge
  • Surgical airway with a cricothyroidotomy is only performed in the rare cases where intubation cannot be performed properly.

enlarge

Conscious patient–Endotracheal intubation

If the patient is conscious but the airway still obstructed, an endotracheal intubation should be performed by qualified personnel and under anaesthesia.

4 When the airway is patent top

enlarge

If the airway is patent:

  1. administer O2 (100 %, 12 L/min)
  2. The neck is immobilized using a cervical collar of the correct size.
  3. Pulse oximetry monitoring is initiated
  4. Patient is re-examined and if oxygen saturation < 95 %, evaluate whether this is caused by airway obstruction. Hypoxemia may also be caused by inadequate ventilation (Breathing), and/or Circulatory problems.
  5. Proceed to evaluate breathing.

2016-10-20