Executive Editor: Steve Krikler

Authors: Renato Fricker, Jesse Jupiter, Matej Kastelec

Distal forearm 23-A1.3 ORIF

back to skeleton

Glossary

1 Preliminary remarks top

enlarge

Comminuted fractures of the distal ulna usually occur in combination with distal radial fractures.

In multifragmentary ulnar fractures, there is instability and shortening, so the distal ulnar hook plate may be useful to hold distal multifragmentary fractures.

Attention should be paid to restoring correct rotation and correct length in relation to the radius.

Complete dislocation of the radiocarpal joint is often associated with disruption of the distal radioulnar joint (DRUJ).

2 Open Reduction top

enlarge

Under direct visualization, the ulnar head is reduced to the ulnar shaft using a small periosteal elevator or a dental pick. In multifragmentary subcapital fractures, correct alignment and correct rotational alignment of the head is verified.

A reduction forceps is usually not applicable due to the small fragments and the soft bone quality at this level.


enlarge

Temporary stabilization with a small K-wire may be helpful, especially if there is a separate ulnar styloid fragment.

3 Internal fixation top

enlarge

Hook plate

The distal ulna hook plate is a precontoured plate that fits to the surface of the distal ulna and allows grasping of the ulnar styloid with the pointed hooks.


enlarge

Plate application

The pointed hooks are placed around the tip of the ulnar styloid and the plate is aligned on the ulnar shaft.


enlarge

Handling of the plate may be facilitated using the LCP drill sleeve inserted in one of the LCP plate holes.

Image intensification may be used to verify correct plate position.


enlarge

Screw insertion

An LCP drill sleeve is used to drill a hole for a locking screw in the ulnar head.  Avoid drilling through the opposite cortex, as the screw tip would penetrate into the distal radioulnar joint.

Screw length is measured pushing the hook of the depth gauge against the opposite cortex. A slightly shorter screw is then chosen.


enlarge

The first locking head screw is inserted into the ulnar head.


enlarge

A standard screw is inserted through the oblong plate hole to reduce the shaft fragment to the plate.

At this point reduction is verified under image intensification and unrestricted pronation and supination is checked.


enlarge

Additional locking head screws are inserted into the ulnar head and fixation at the shaft fragment is completed using standard or locking head screws.


enlarge

Option

A 1.5 mm screw may be inserted between the pointed hooks of the plate to provide additional stability to the fixation of the ulnar styloid fragment.
 
In this case, the most distal locking head screw cannot be inserted.


enlarge

Pearl: Retaining the K-wire

If a K-wire has been used for the fixation of the ulnar styloid, the K- wire may be left in place, if it enters the ulnar styloid between the pointed hooks. The K-wire is then bent and cut short. 


enlarge

Pitfall: First locking head screw too long

If the screw penetrates the opposite cortex of the ulnar head, the screw tip will damage the cartilage of the radioulnar joint.