Executive Editor: Steve Krikler

Authors: Renato Fricker, Jesse Jupiter, Matej Kastelec

Distal forearm 23-B1.3 ORIF

back to skeleton

Glossary

1 Preliminary Remarks top

enlarge

Fracture assessment

A B1.3 fracture is a partial articular injury involving the ulnar column of the distal radius, so affects both the radiocarpal and distal radioulnar joints. The fixation needs to resist the shearing forces to which the fragment is subjected.

An isolated fracture of the lunate facet of the distal radius results from a direct axial impaction by the carpal lunate.

CT scans are strongly recommended to define this unusual articular injury better.


enlarge

Provisional reduction in displaced fractures

Reduction is achieved by applying longitudinal traction either manually or using Chinese finger traps.

The reduction is maintained by a temporary splint.

If definitive surgery is planned, but cannot be performed within a reasonable time scale, a temporary external fixator may be helpful.

2 Associated injuries top

enlarge

Median nerve compression

If there is dense sensory loss, or other signs of median nerve compression, the median nerve should be decompressed.


enlarge

Associated carpal injuries

These injuries may be associated with shearing injuries of the articular cartilage, scaphoid fracture and rupture of the scapholunate ligament (SL). Every patient should be assessed for this injury. If present, see carpal bones of the Hand module.


enlarge

DRUJ/ulnar injuries

These injuries may be accompanied by avulsion of the ulnar styloid and/or disruption of the DRUJ. If there is gross instability after the fixation of the radial fracture, it is recommended that the styloid and/or the triangular fibrocartilaginous disc (TFC) is reattached (see A1.1). This is not common in simple fractures, but may occur with some high energy injuries.

The uninjured side should be tested as a reference for the injured side.

It may not be possible to assess DRUJ stability until the fracture has been stabilized (as described below).

3 Reduction top

enlarge

Periosteal elevator

If necessary, use a periosteal elevator to disimpact and elevate the dorsoulnar fragment.


enlarge

Provisional K-wire fixation

Insert a K-wire to hold the fragment provisionally.
Confirm reduction using image intensification.

If in doubt about congruity of the articular surface under image intensification it is mandatory to open up the joint (dorsal capsulotomy).

4 Plate positioning and contouring top

enlarge

Plate contouring

Many plates are available for this fracture, some with locking screws. The most recently designed plates have variable angle locking screws.

Because of the shape of the dorsal distal metaphysis, the plate may need to be adapted to fit the bone surface and the proximal limb may require some torsional adaptation.


enlarge

An appropriately sized L-plate is chosen, preferably one with locking holes distally.

If the plate being used has fixed angle locking screws, there is a risk that the screws may penetrate the joint. To prevent this, the distal limb of the plate must be bent to ensure the screws are parallel to the joint surface.

To avoid this problem, the use of variable angle plate is recommended.


enlarge

Pitfall: Screw hole distortion

Avoid contouring the plate through the locking holes, otherwise the locking head screw might not fit any more.


enlarge

Plate position

The plate should be applied as distal and as ulnarward as possible onto the dorsoulnar column of the distal radius.

5 Plate fixation top

enlarge

Insert a screw through the oblong plate hole, using a screw long enough to engage the opposite cortex. Do not fully tighten the screw yet.

Confirm the reduction and plate position using image intensification. If necessary, adjust the plate position until it is as distal and as ulnar as possible. Now tighten the screw.


enlarge

Insert proximal screw

A screw is inserted through the most proximal plate hole.


enlarge

Insert distal screw

Insert a distal screw.


enlarge

Confirm screw position

Confirm using image intensification that the distal screw has not penetrated the articular surface. In order to have a view in line with the articular surface, the beam should be angled 20º from the true lateral.


enlarge

Depending on the fragment size, an additional distal variable angle locking screw may be inserted.

6 Assessment of Distal Radioulnar Joint (DRUJ) top

Before starting the operation the uninjured side should be tested as a reference for the injured side.

After fixation, the distal radioulnar joint should be assessed for forearm rotation, as well as for stability. The forearm should be rotated completely to make certain there is no anatomical block.


enlarge

Method 1

The elbow is flexed 90° on the arm table and displacement in dorsal palmar direction is tested in a neutral rotation of the forearm with the wrist in neutral position.

This is repeated with the wrist in radial deviation, which stabilizes the DRUJ, if the ulnar collateral complex (TFCC) is not disrupted.


enlarge

This is repeated with the wrist in full supination and full pronation.


enlarge

Method 2

In order to test the stability of the distal radioulnar joint, the ulna is compressed against the radius...


enlarge

...while the forearm is passively put through full supination...


enlarge

...and pronation.

If there is a palpable “clunk”, then instability of the distal radioulnar joint should be considered. This would be an indication for internal fixation of an ulnar styloid fracture at its base. If the fracture is at the tip of the ulnar styloid consider TFCC stabilization.