Executive Editor: Peter Trafton

Authors: Kodi Kojima, Steve Velkes

Proximal forearm 21-A2.3 ORIF

back to skeleton

Glossary

1 Bridge plating principles top

enlarge

In multifragmentary fractures of the radial neck, fixation of the radial head to the diaphysis is achieved by bridge plating.

Bridge plating uses the plate as an extramedullary splint, fixed to the two main fragments, while the intermediate fracture zone is left untouched.

Anatomical reduction of the intermediate fragments is not necessary but alignment, rotation and length of the radius must be restored.

2 Plate positioning top

enlarge

The radial head is completely covered by articular cartilage. The implant is applied to the radial head in a location that causes the least compromise of full pronation and supination.

Safe zone for plate and screw insertion

To determine the location of the "safe zone“, reference marks are made along the radial head and neck, to mark the midpoint of the visible bone surface. Three such marks are made with the forearm in neutral rotation, full pronation, and full supination as shown in the illustration.

The posterior limit of the safe zone lies halfway between the reference marks made with the forearm in neutral rotation and full pronation. The anterior limit lies nearly two thirds of the distance between the neutral mark and the mark made in full supination.

Note
The nonarticulating portion of the safe zone for the application of implants to the radial head (or safe zone for prominent fixation) consistently encompasses a 90 degrees angle localized by palpation of the radial styloid and Lister's tubercle.

3 Choice of implant top

enlarge

As the radial head is a small fragment, a mini fragment 1.5 or 2.0 T-plate, or a locking proximal radius plate is used to allow purchase of two or three screws in the proximal fragment.

The plate length depends on the fracture fragmentation. With a larger fracture zone, a longer plate has to be chosen.

Prebend the plate according to the surface anatomy of the proximal radius.

4 Reduction and fixation top

enlarge

Indirect reduction

In multifragmentary radial neck fractures, indirect reduction is performed. Apply the prebent plate with two or three screws to the radial head.
With the help of reduction forceps, adjust the plate to the diaphysis correcting length, rotation, and alignment.


enlarge

Distal fixation

Fix the plate with two or three bicortical 1.5 or 2.0 mm screws to the distal fragment.


Final assessment

Following fracture and ligament repair, elbow stability should be assessed through a full range of flexion-extension. Radiocapitellar and ulnohumeral joints should remain located.

Also check supination and pronation. Fixation should be stable. Crepitus or restricted motion should be absent.

Check fracture and fixation with image intensifier or x-ray.

v1.0 2007-10-14