General Editor: Luiz Vialle

Authors: Ilya Laufer, JJ Verlaan (on behalf of AOSpine Knowledge Forum Tumor)

Metastatic tumors Occipitocervical, unstable, low ESCC

back to Spine overview

Glossary

1 Introduction top

enlarge

Preoperative planning

Based on CT and MRI imaging, a plan should be prepared to determine:

  • The size and optimal location of implants used
  • Whether spinal cord decompression is necessary and if so, the amount of tissue to remove in order to achieve sufficient spinal cord decompression

Every case will be unique, and we will here illustrate just one example.

2 Patient positioning and approach top

enlarge

This procedure is performed with the patient placed prone through a posterior approach.

3 Occipital fixation top

enlarge

Occipital plate

There are several plate systems available for the occiput. Their application is based on the same principles and to illustrate these concepts, we will show the use of plate placed in the midline which allows for modularity and rotation when connecting to the rods.


enlarge

Plate placement

Independently of the plate system used, its placement should be close to but still caudal to the external occipital protuberance (EOP).

Placement of the plate at the EOP will increase the risk of erosion of the skin.

A too caudal position may compromise the foramen magnum.

 


enlarge

Screw placement

The thickest part of the cranium is the dense ridge which runs vertically in line with the internal occipital crest.

The thickness of this crest is 11.5-15 mm in males and 10-12 mm in females and provides the best bone stock for screw purchase.

As you move laterally this crest becomes thinner and around 7-8 laterally to the midline, the bone thins out to a thickness of only 5-6 mm.


enlarge

Another landmark with thicker bone is the superior nuchal line which runs horizontally.

4 Plate application top

enlarge

The midline of the posterior aspect of the skull which is in line with the EOP is identified.

The plate is placed centered in the midline on the posterior aspect of the occiput. This allows for optimal placement, sizing and shape of the plate.


enlarge

Once the optimal plate is chosen, the location of the central cranial screw entry point is marked with the plate in place. 


enlarge

The drill guide is set to 8 mm (female) or 10 mm (male) and the central cranial screw hole drilled.


enlarge

The screw hole is probed to verify that the anterior cortex is still intact.


enlarge

If intact, additional drilling in 2 mm increments is performed until the anterior cortex is penetrated.


enlarge

A screw of appropriate length is inserted through the plate into the predrilled hole. 


enlarge

After insertion of the first screw, there is enough flexibility in the system to allow for adjustments. Ensure the plate is flush with the skull and that it is level. 


enlarge

The remaining screws are then inserted with the same drill technique as for the first screw ensuring bicortical purchase in the order 2-5.

However, care is taken during drilling of the lateral holes (2 and 3) as the bone will be thinner than in the midline (4 and 5). 

5 Cervical screw fixation top

enlarge

C1 fixation

The C1 level is rarely included in the instrumentation for C1 and C2 tumors.

However, an uncompromised lateral mass may be instrumented upon surgeon's preference.


enlarge

C2 fixation

For C1 tumors, C2 is instrumented bilaterally.

For C2 tumors, the C2 level is rarely included in the instrumentation. However, if the tumor is unilateral, the contralateral side may be instrumented upon surgeon's preference.

For C2 fixation the following options are available (in order of preference):

A consideration is given to use pedicle or laminar screws when doing an occiput to C2 fusion as oftentimes the starting point for the pars screws may compromise the facet joint.


enlarge

C3 and C4 fixation

Two to three levels inferior to the tumor should be instrumented.

Fixation can be achieved with either lateral mass screws, pedicle screws or combination of the two.

Because lateral mass fixation is generally enough, and carries less risk, pedicle screw fixation is limited to rare cases where lateral mass fixation would be insufficient or not possible.

6 Alignment in the occipital cervical region top

enlarge

If there is a preoperative X-ray available, the surgeon can use this as a guide to properly align the occipito cervical junction during fusion. Ideally proper alignment allows for horizontal gaze.

7 Rod contouring top

enlarge

When the correct alignment is verified, the first rod is inserted. If no fusion is planned, the second rod is also inserted at this point.

8 Fusion top

Indication for fusion

For patients with good prognosis and a long life-expectancy, posterior fusion may optionally be performed using allograft and/or local autograft.


enlarge

Decortication

Decortication of lamina, facets, and posterior aspects of the skull is performed prior to placement of the final rod.


enlarge

When using laminar screw fixation at C2, care must be taken not to decorticate deeply which might compromise screw fixation.


enlarge

Second rod insertion

The second rod is inserted.


enlarge

Bone grafting

Bone grafting material is placed against the decorticated elements of the spine.

V1.0 2019.01.06