Executive Editor: Ernst Raaymakers, Joseph Schatzker, Rick Buckley

Authors: Matthias Hansen, Rodrigo Pesantez

Proximal tibia 41-B1 Indirect reduction

back to skeleton

Glossary

1 Principles top

enlarge

Anatomical reduction

Anatomical reduction of the articular fracture component and fixation with absolute stability is mandatory.

2 Reduction top

enlarge

Single clamp

Indirect reduction may be achieved by external manipulation of the fractured fragment using clamps. In cases where adequate closed reduction is not achieved the joint should be opened to allow anatomical reduction.

Check the reduction either arthroscopically or under image intensification.


enlarge

Multiple clamps

Depending on the fracture configuration more than one clamp may be necessary as shown in the image.


enlarge

Secure reduction with K-wire

Apply a K-wire to secure the reduction and to facilitate cannulated screw fixation.

3 Fixation top

enlarge

Lag screw application

Once anatomic reduction of the fracture is obtained fixation follows with two cancellous screws with washer. In young people screw fixation is enough. In older individuals a buttress plate should be added to prevent displacement.

Use image intensification to check the length and position of the implants.

The cortex in the lateral tibial head is thin. Therefore, the use of washers is needed in the majority of the patients.

Click here for a detailed description of the lag screw technique.

v2.0 2010-05-15