page: 1/3 next

Fixation

Apply compression

Insert the first screw into the fragment which forms a blunt angle with the plate. The screw is inserted into the hole closest to the fracture site.

Insert the second screw eccentrically near the fracture in the fragment forming an acute angle with the plate.

Tightening the screws will compress the fracture.