enlarge

Position of the plate

Use a seven or eight hole one-third tubular plate that can be positioned laterally, so that three screws find a secure hold in the distal fragment and three in the proximal fragment.


enlarge

Contouring the plate

Before the plate is applied, it must be contoured with the help of an appropriate aluminum template.

The plate is contoured according to the shape of the fibula. It should fit perfectly onto the bone contour throughout its entire length.